accQcomm™Interface ModuleInstallation and Operation GuidePart #69-7503-015 of Assembly #60-7504-015Copyright © 2007. All rights reserved, Teledyne Isc
accQcomm Interface ModuleSection 1 Introduction1-41.4 Unpacking InstructionsWhen the system arrives, inspect the outside packing for anydamage. When
accQcomm Interface ModuleSection 1 Introduction1-51.5 Technical SpecificationsTable 1-1 lists the technical specifications for the accQcomm.Table 1-1
accQcomm Interface ModuleSection 1 Introduction1-6
2-1accQcomm Interface ModuleSection 2 Installation and Operation2.1 Programming The accQcomm’s configuration software is a simple program formanaging
accQcomm Interface ModuleSection 2 Installation and Operation2-22.2 Site Setup Begin creating a site file for the flow meter(s) connected to theaccQc
accQcomm Interface ModuleSection 2 Installation and Operation2-32.2.2 Display Units In the Display Units box (Figure 2-2), click the pull-down menust
accQcomm Interface ModuleSection 2 Installation and Operation2-4Totalizer Mode There are three selectable totalizer modes:Net – Total flow includes b
accQcomm Interface ModuleSection 2 Installation and Operation2-5Instruments 2 and 3, when first made active, will have thedefault name of INACTIVE, w
accQcomm Interface ModuleSection 2 Installation and Operation2-62.3 Communication Click the Communication tab to select the appropriate commu-nicatio
accQcomm Interface ModuleSection 2 Installation and Operation2-7Flow Control can be used when the accQcomm is communicatingthrough a modem, to regula
accQcomm Interface ModuleSection 2 Installation and Operation2-82.4 Alarms The accQcomm has eight programmable relays for triggeringalarms based on o
accQcomm Interface ModuleSection 2 Installation and Operation2-9When you highlight the desired alarm number in the CurrentAlarms window and click Set
accQcomm Interface ModuleSection 2 Installation and Operation2-10Alternate MODBUS Port Although ordinarily only MODBUS or Analog output (see nextsect
accQcomm Interface ModuleSection 2 Installation and Operation2-11Ranges are user-defined using the 4mA and 20mA boxes.Parameter values will be displa
accQcomm Interface ModuleSection 2 Installation and Operation2-12NoteFor the accQmin flow meter, the accQcomm displays andtransmits secondary level d
accQcomm Interface ModuleSection 2 Installation and Operation2-132.6 Smoothing The smoothing function stabilizes data outputs by disregardingbrief sp
accQcomm Interface ModuleSection 2 Installation and Operation2-14When selecting the TCF, keep in mind that the system’s responseto any change within
accQcomm Interface ModuleSection 2 Installation and Operation2-152.7 Alarm and Output ParametersTable 2-2 contains the parameters shown in the pull-d
accQcomm Interface ModuleSection 2 Installation and Operation2-162.8 Viewing Data Via EthernetTo view your flow data via LAN or Internet connection,
accQcomm Interface ModuleSection 2 Installation and Operation2-17Figure 2-12 Summary page in Web view
ForewordThis instruction manual is designed to help you gain a thorough understanding of theoperation of the equipment. Teledyne Isco recommends that
accQcomm Interface ModuleSection 2 Installation and Operation2-18For each connected instrument, the table will provide links toadditional data (Figur
accQcomm Interface ModuleSection 2 Installation and Operation2-19Figure 2-14 Viewing historical site dataThe accQcomm will store the last 100 reading
accQcomm Interface ModuleSection 2 Installation and Operation2-20Figure 2-15 accQcomm reset buttonAfter a brief pause, the LCD will display:2. While
accQcomm Interface ModuleSection 2 Installation and Operation2-21After a few seconds, the LCD will change to display:Once the accQcomm has moved past
accQcomm Interface ModuleSection 2 Installation and Operation2-22
A-1accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA.1 Program Commands Teledyne Isco recommends using the accQcomm configurati
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-2AS“Big Step” ConstantParam 1: A big step value for flow measurements. Change
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-3LDConfigures the LCD DisplayParam 1 (0 or 1): Toggles the Instrument 1 displ
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-4RCSet one alarm condition for flow pulse output to a samplerNOTE: Condition
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-5SBInitialize modemParam 1 (String): A command string used to initialize the
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-6SPSerial port configurationParam 1 (Range 0 to 3): The serial port that is b
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-7A.2 Data Type Constants Table A-2 lists all of the parameters that can be sp
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-8A.3 MODBUS Register LocationsTable A-3 on the following page lists all avail
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-9A.3.1 Explanation of an Example Output ReadingAssume the current flow rate v
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-10Table A-3 MODBUS Register AddressesData Type Data Value Instrument 1 Instru
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-11Electronics Temperature 30028 30078 30128Voltage Voltage 30029 30079 30129S
accQcomm Interface ModuleAppendix A Commands, Constants, and RegistersA-12
B-1accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replace-ment PartsEquipment, accessories, and replacement parts can be purchasedby
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-2B.1 Equipment and AccessoriesaccQcomm Interface Module . . . . .
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-3B.2 Replacement Parts Diagrams and ListingsReplacement parts are
vaccQcomm Interface ModuleTable of ContentsSection 1 Introduction1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-4
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-5
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-6
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-7
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-8
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-9
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-10
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-11
accQcomm Interface ModuleAppendix B Equipment, Accessories, and Replacement PartsB-12
Index-1accQcomm Interface ModuleIndexNumerics4-20 mA output, 2-10Aalarms, 2-8command mode, A-4example, 2-8, A-4analog output, 2-10Bbad data, 2-14Ccabl
accQcomm Interface ModuleTable of ContentsviList of Figures1-1 accQcomm connectors and cables . . . . . . . . . . . . . . . . . . . . . . . . . . .
accQcomm Interface ModuleIndexIndex-2Ttechnical specifications, 1-5totalizer, 2-3reset, 2-4Uunits of measure, 2-3unpacking instructions, 1-4WWeb viewi
Compliance StatementsCE Declaration of ConformityDECLARATION OF CONFORMITY Application of Council Directive: 89/336/EEC – The EMC Directive 73/23/
War ran tyBefore returning any instrument for repair, please call, fax, or e-mail the Teledyne Isco ServiceDepartment for instructions. Many problems
1-1accQcomm Interface ModuleSection 1 Introduction1.1 Overview The accQcomm Interface Module is an optional component of anH-ADFM/ADFM/accQmin Velocit
accQcomm Interface ModuleSection 1 Introduction1-21.2 Outputs The accQcomm has an array of outputs for different data types,summarized below. For det
accQcomm Interface ModuleSection 1 Introduction1-3Figure 1-1 accQcomm connectors and cablesNoteNegative System Power must be connected to ChassisGrou