59
Rosenberger
HDCS
®
Data Cable
304&/#&3(&3
)%$4
®
$"#-*/(4:45&.
High Frequency Performance at 20
ą
Frequency
(MHz)
Attenuation
(dB/100m)
NEXT
(dB)
RL
(dB)
PSNEXT
(dB)
ELFEXT
(dB)
PSELFEXT
(dB)
ACR
(dB)
Propagation
Delay
(ns/100m)
Max. Min. Min. Min. Min. Min. Min. Max.
1.0 2.0 74.3 20.0 72.3 67.8 64.8 72 570.0
4.0 3.8 65.3 23.0 63.3 55.8 52.8 61 552.0
8.0 5.3 60.8 24.5 58.8 49.7 46.7 55 546.7
10.0 6.0 59.3 25.0 57.3 47.8 44.8 53 545.4
16.0 7.6 56.2 25.0 54.2 43.7 40.7 49 543.0
20.0 8.5 54.8 25.0 52.8 41.8 38.8 46 542.0
25.0 9.5 53.3 24.3 51.3 39.8 36.8 44 541.2
31.25 10.7 51.9 23.6 49.9 37.9 34.9 41 540.4
62.5 15.4 47.4 21.5 45.4 31.9 28.9 32 538.6
100.0 19.8 44.3 20.1 42.3 27.8 24.8 25 537.6
150 24.7 41.7 18.9 39.7 24.3 21.3 16.9 536.9
200 29.0 39.8 18.0 37.8 21.8 18.8 10.8 536.5
250 32.8 38.3 17.3 36.3 19.8 16.8 5.5 536.3
300 35.0 37.5 17.0 35.5 19.2 15.5 2.5 536.1
600 53.1 33.0 15.0 32.5 11.0 9.5 -20 535.5
Characteristic Graph
Ordering Information
Order Number Description
CP12-141-11 CAT.6 outdoor UTP cable, PE, 305m
CP11-141-12 CAT.6 indoor UTP cable, CM, 305m
CP11-141-13 CAT.6 indoor UTP cable, LSZH, 305m
CP11-141-14 CAT.6 indoor UTP cable, CMR, 305m
CP11-141-16 CAT.6 indoor UTP cable, CMP, 305m
Comentários a estes Manuais